5. Save the Results
Tap SAVE if the test passed or FIX LATER if the test failed. The tester saves
the results in the DEFAULT project, unless you selected a different project.
Registration
Registering your product with Fluke Networks gives you access to valuable
information on product updates, troubleshooting tips, and other support
services.
To register, use LinkWare PC software. Download LinkWare PC from the Fluke
Networks website.
Contact Fluke Networks
»
www.ukenetworks.com/support
info@ukenetworks.com
1-800-283-5853, +1-425-446-5500
Fluke Networks
6920 Seaway Boulevard, MS 143F
Everett WA 98203 USA
Fluke Networks operates in more than 50 countries worldwide. For more
contact information, visit our website.
General Specications
Battery
Type: Lithium-ion
Charging Temperature: 0 °C to +45 °C (+32 °F to +113 °F)
Power
Adapter
Input: 100 to 240 VAC ±10%, 50/60Hz
Output: 15 VDC, 2 A maximum
Class II
Versiv 2
wireless
radio*
Frequency ranges:
2.4 GHz band: 2412 MHz to 2484 MHz
5 GHz band: 4910 MHz to 5825 MHz
Output power: <100 mW
Temperature
Operating: -10 °C to +45 °C (+14 °F to +113 °F)
Storage: -10 °C to +60 °C (+14 °F to +140 °F)
Altitude
Operating: 4,000 m (3,200 m with AC adapter)
Storage: 12,000 m
* For more information, go to www.flukenetworks.com/manuals and search for
“Radio Frequency Data for Class A”.
5