Data Test
Connect the unit to Tip and Ring and move the T/M
switch to T. If high speed data is present, the unit’s
alarm will start beeping and the unit will lockout
and not go off-hook. If there is no high speed data,
the unit will go off-hook.
Data Lockout Override
In Talk mode, while the data lockout alarm is
sounding, press the OVERRIDE key – the unit will
go off-hook. For example, this is what you would
do to access POTS on a line carrying both POTS and
ADSL.
Line Voltage Test
In Monitor mode, press Vdc&mA/TEST key.
Low Voltage
0 Vdc to 2 Vdc - LO LED lights up red for 3 sec-
onds.
2 Vdc to 42 Vdc - LO LED flashes red.
Normal Voltage
42 Vdc to 53 Vdc - LO and HI LEDs flash green
once.
High Voltage
53 Vdc to 140 Vdc - HI LED flashes red.
>140 Vdc - HI LED lights up red for 3 seconds.
Loop Current Test
Go off-hook and press the Vdc&mA TEST key.
If the loop current is less than 23mA, the mA LED
flashes red. If the loop current is greater than
23mA, the mA LED flashes green.

Other manuals for Fluke TS 44 PRO

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fluke TS 44 PRO and is the answer not in the manual?

Fluke TS 44 PRO Specifications

General IconGeneral
BrandFluke
ModelTS 44 PRO
CategoryTest Equipment
LanguageEnglish

Related product manuals