Operating Instruction Flytec 6005/6010 25
Technical Data
Size: 4-3/8 x 2-3/4 x 13/16 inches (138 x 74 x 23 mm)
Weight: 6.278 ounces (178 grams) (with 2 alkaline batteries,
without mountings)
Electrical Power Supply: 2 AA alkaline batteries AA or NiMH batteries
Battery Life: > 250 hours with 2 alkaline batteries
Altimeter: max. 37,700 feet (11,500 m), 3 ft (1 m) steps
QNH air pressure: hPa or inHg
Variometer: analog ± 2,000 ft/min (10 m/s), 40 ft/min (0.2 m/s) steps
digital ± 19,200 ft/min (96 m/s), 10 ft/min (0.1 m/s) steps
Integrator (Vario Averager): adjustable from 1 sec to 30 sec
Speed Display: digital, 0 to 99 mph (160 km/h),
displayed in km/h, kts or mph
resolution: 1 mph, 1 km/h or, 1 kts
calibration range ± 50%
Temperature Display: -72.4°F to 168.8°F (- 50° C to 76° C)
units: °F or °C
resolution: 0.1°F (0.1°C)
accuracy: ± 0.5° C, calibration possible
Time Functions: real time clock (12h/24h) with date
stop watch up to 99 hrs 59 min 59 sec
automatic calendar, automatic logging
Max. Barograph Recording 130 hours. flying time
Time [6010]: recording interval: 1 sec, 5 sec or 15 sec
recording of altitude, altitude and speed, or altitude and
temperature
Number of Logged Flights: 40 with date, start time, flying time, max. altitude and
min./max. vario
Operating Temperature Range: F to 140°F (-15°C to +60 °C)
Storage Temperature Range: -22°F to 158°F (-30°C to +70 °C)
Brackets and airspeed sensors for hang gliders and paragliders are available.
The technical data may be changed at any time.