Specications
Dimensions
REF1 REF2
Dimensions (external)
18.6" W x 24" D x 17.93" H
(47 cm x 61 cm x 46 cm)
18.6" W x 24" D x 27.93" H
(47 cm x 61 cm x 71 cm)
Dimensions (internal)
14.5" W x 10" D x 11.25" H
(37 cm x 26 cm x 28.6 cm)
14.5" W x 10" D x 21.25" H
(37 cm x 26 cm x 54 cm)
Shelf Size
13.75 W x 9 D
(35 cm x 23 cm)
13.75 W x 9 D
(35 cm x 23 cm)
Capacity 1 cu ft (28 L) 1.8 cu ft (51 L)
Weight (uncrated)* 73 lbs (33 kg) 87 lbs (39 kg)
* Add 22 lbs/10 kg for packaging.
Electrical Specications
§ 115 V, 60 Hz, 1 phase
§ Full load: 1.8A
§ Minimum circuit ampacity: 15A
§ Connect to dedicated circuit, fuse or breaker
§ Maximum size of branch circuit overcurrent device: 15A
§ Follett recommends circuit be protected by GFCI.
Refrigeration Specications
Refrigerant Charge Size (oz)
Maximum Design Pressures (psi)
High Side Low Side
R134A 3.4 240 88
Heat Rejection
§ 190 BTU/hr (56 W) maximum
Ambient Information
CAUTION!
The REF1 and REF2 are for indoor use only.
Optimum Maximum
Air Temperature ≤80 F (27 C) 100 F (38 C)
Relative Humidity 60% max
Installation
Locating the Refrigerator
Performance of REF1 and REF2 is affected by ambient temperature and location. To ensure proper
performance, please refer to the following drawings and conrm that the clearance requirements are met. There
is no clearance requirement for the back of the refrigerator so it can be placed against the wall.
80 F (27 C) and 60% RH – located under overhanging cabinet or shelf with zero top clearance
Requires 6" (15.3 cm) clearance on either right or left side
2 REF1/REF2 Compact Refrigerators