EasyManua.ls Logo

Follett REF2 - User Manual

Follett REF2
32 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
REF1 REF2
Order parts online:
www.follettice.com
00940593R14
801 Church Lane • Easton, PA 18040, USA
Toll free (877) 612-5086 • +1 (610) 252-7301
www.follettice.com
Following installation, please forward this manual
totheappropriate operations person.
Installation, Operation and Service Manual
After Serial Number H55798
REF1/REF2
High-Performance Compact Refrigerators

Other manuals for Follett REF2

Questions and Answers

  • C
    Christopher HayesAug 13, 2025
    What to do if my Follett Refrigerator does not operate?
    • R
      robert53Aug 13, 2025
      If your Follett Refrigerator isn't running, first, check if the power switch is turned ON and ensure it's properly connected. Also, verify that the refrigerator is plugged into a working outlet and that there is power to the cord. If these steps don't solve the issue, the temperature controller might not be energizing the components, so check the controller contact terminals for power and replace the controller if necessary. Finally, the probe may not be sensing the set point temperature, in which case you should replace the controller and/or probe.
  • J
    James GardnerAug 21, 2025
    What to do if the compressor does not run in my Follett REF2?
    • N
      nicholedouglasAug 21, 2025
      If the compressor in your Follett Refrigerator isn't running, the thermal overload may be open or defective; allow it to cool or replace it. Also, the capacitor and/or relay could be defective, so replace them as required. If neither of those steps work, the compressor itself may be defective and require replacement.
  • D
    Danielle MooreAug 25, 2025
    Why won't my Follett REF2 Refrigerator shut off?
    • J
      jamie24Aug 25, 2025
      If your Follett Refrigerator won't shut off, the controller may not be sensing the cut-off temperature, so replace the controller and/or probe. Alternatively, the controller might be keeping the refrigeration system energized, in which case you should replace the controller.
  • G
    Gabrielle SmithAug 28, 2025
    How to fix an evaporator fan motor that doesn't run in a Follett REF2 Refrigerator?
    • C
      Corey WhitakerAug 28, 2025
      If the evaporator fan motor in your Follett Refrigerator isn't running, the fan motor is likely defective and needs to be replaced.
  • C
    Cory AustinSep 1, 2025
    Why is my Follett Refrigerator not maintaining temperature even though all components are running?
    • S
      Steven GillSep 1, 2025
      Your Follett Refrigerator might not be maintaining the correct temperature due to several reasons. The condensor or evaporator coil may need cleaning. Another possible cause is a faulty door gasket, which should be replaced. Also, excessively high ambient temperature or inadequate air clearance can be the reason. The maximum recommended ambient temperature is 100 F (38 C). A refrigerant leak or incorrect refrigerant charge could also be the cause. In this case you should locate and repair the leak, or recover, evaluate, and weigh in the correct charge. Other possible causes are a plugged capillary tube (replace capillary tube and filter drier) or an inefficient compressor (consult technical services).
  • D
    Daniel HodgesSep 4, 2025
    What to do if my Follett Refrigerator does not operate at all?
    • J
      James Cruz IISep 4, 2025
      If your Follett Refrigerator isn't operating, start by checking the power switch to ensure it's in the ON position and that all connections are secure. If that's not the issue, make sure the refrigerator is properly plugged in and that there is power to the cord. If the issue persists, the temperature controller might not be energizing the components; check the controller contact terminals for power and replace the controller if needed. It's also possible that the probe isn't sensing the set point temperature, in which case you should replace the controller and/or probe.
  • C
    Curtis DaltonSep 8, 2025
    What causes the compressor to not run on a Follett REF2?
    • R
      Robert JacksonSep 8, 2025
      If the compressor in your Follett Refrigerator isn't running, the thermal overload may be open or defective; allow it to cool or replace it. Alternatively, the capacitor and/or relay could be defective, requiring replacement as needed. In some cases, the compressor itself may be defective, necessitating its replacement.
  • S
    Scott SantiagoNov 16, 2025
    Why my Follett Refrigerator does not maintain temperature?
    • S
      Sandra BradyNov 16, 2025
      If your Follett Refrigerator is running but not maintaining the correct temperature, begin by cleaning the condenser or evaporator coils. Next, inspect the door gasket for faults and replace it if necessary. Ensure the ambient temperature isn't excessively high and that there's adequate air clearance. The maximum recommended ambient temperature is 100°F (38°C). If these steps do not resolve the issue, there may be a refrigerant leak, which requires locating and repairing the leak. Alternatively, the refrigerant charge may be incorrect, needing recovery, evaluation, and weighing in the correct charge. Other potential issues include a plugged capillary tube, which would require replacing the capillary tube and filter drier, or an inefficient compressor, which would require technical services...

Summary

Welcome to Follett

Specifications

Dimensions

Detailed dimensions for REF1 and REF2 models, including external and internal measurements.

Electrical Specifications

Electrical requirements, ampacity, circuit protection, and GFCI recommendations.

Refrigeration Specifications

Details refrigerant type, charge size, and maximum design pressures.

Heat Rejection

Specifies the maximum heat rejection rate in BTU/hr.

Ambient Information

Outlines recommended air temperature and relative humidity ranges for operation.

Installation

Locating the Refrigerator

Provides clearance requirements and placement guidelines based on ambient conditions for optimal performance.

Installing Shelves

Step-by-step guide on how to install shelves and shelf brackets inside the refrigerator.

Installing Glycerine Solution in Product Simulation Bottle

Instructions for filling and installing the glycerine solution bottle for product simulation.

Battery Backup (KP models only)

Details the procedure for installing the battery backup system for KP models.

Reversing the Door Swing - Optional

Provides instructions and warnings for reversing the door swing on the refrigerator.

Adjusting Hinge Closure Force

Instructions on how to adjust the hinge closure force for proper door operation.

Installing Third-party Temperature Probe

Guide for installing a third-party temperature probe for monitoring systems.

Cleaning

Interior and Exterior Cleaning

Instructions for cleaning the interior with detergent and exterior with a soft cloth.

Annual Cleaning

Procedure for deep cleaning the unit, including drain pan and condenser, annually.

Periodic Cleaning-Patient Room Models

Specific guidelines for periodic condensate pan cleaning in PR models.

Operation

Temperature Control and Defrost

Explains temperature control, factory settings, and automatic defrost functionality.

Controller Operation and Display

Details how to operate the controller, its display indicators, and pre-programmed set points.

Controller Security

Explains how to lock and unlock the controller to prevent unauthorized set-point changes.

Temperature Display Settings

Instructions for changing temperature display between Celsius/Fahrenheit and Decimal/Integer.

Sleep Function

Describes how to use the sleep function to blank the display and wake it.

Minimum and Maximum Temperature Logging

How to view and reset the logged minimum and maximum temperatures.

Alarming Functions and Codes

Details setting alarms, muting, acknowledging, and understanding alarm/error codes.

Alarming Contacts - Optional Accessory

Information on using dry contacts for external alarm monitoring systems.

Advanced Settings

Guide to customizing controller parameters like beeper function, volume, and button clicks.

Advanced Settings Parameters

Lists and describes advanced parameters such as alarm delays, functions, and reset options.

Follett Keypad Lock

Instructions for changing the master code and user codes for keypad security.

Service

Door Gasket Replacement

Steps for removing and installing a new door gasket to ensure a proper seal.

Access Compressor Compartment

Procedure to access the compressor compartment for service without cutting refrigerant lines.

Changing the Back-up Batteries

Instructions for replacing the AA batteries in the battery backup pack.

Controller Replacement

Steps for safely removing and replacing the main control module.

Wiring Diagram

Checking Refrigeration System Pressures

Compressor Information

Provides specifications for the Danfoss compressor, including amps and winding resistances.

Refrigerator Troubleshooting

Accessories

Replacement Parts

Hardware

A detailed list of hardware components with reference numbers and part numbers.

Evaporator

Compressor Components

Control Board

Warranty Registration and Equipment Evaluation