3. Insert pin into an open hole nearest the hinge bracket
(Fig.15.1), and remove the tool used to torque the spring
(Fig.15.2).
4. Repeat Steps 2 and 3 until desired closure force is achieved.
CAUTION!
Do not overtorque the spring unnecessarily. Minimum closure
force should close door when door is opened 1" (2.5 cm).
Fig. 15
1
2
5. Reinstall hinge cover (Fig. 16). Fig. 16
Installing Third-party Temperature Probe
Facilities using a third-party alarming and/or temperature monitoring
system need to install the third-party probe in the refrigerator. Follett
recommends removing any stored product before performing this
procedure.
1. Move the power switch on lower rear panel to OFF and unplug
the refrigerator.
2. Remove the rear panel of the refrigerator (Fig. 17).
3. Open front door of refrigerator and remove shelf/shelves, if
installed, for better access.
Fig. 17