18 REF4P, REF5P and REF5BBP-T Undercounter Refrigerators
To Enter or Change a User Code
1. Press 3 6 5, the
*
, followed by the Master Code, followed by ENTER. 5 Chirps will be heard.
2. Enter the user ID (a two digit code from 00 to 40), followed by ENTER. 3 chirps will be heard.
3. Enter the new user code (4 to 6 numbers), followed by ENTER. 3 chirps will be heard.
4. Re-Enter the new User Code, Followed by ENTER. 5 chirps will be heard to acknowledge that a new
code was entered.
Example: To enter a new user code of 4 4 3 3 5 5 for ID # 15
1. Press 3 6 5
*
1 2 3 4 5 6 [ENTER] (5 chirps will be heard).
2. Press 1 5 [ENTER] (3 chirps will be heard).
3. Press 4 4 3 3 5 5 [ENTER] (3 chirps will be heard).
4. Press 4 4 3 3 5 5 [ENTER] (5 chirps will be heard).
The new code has been entered for the ID.
To Delete a User Code
1. Press 3 6 5, the
*
, followed by the Master Code, followed by ENTER. 5 Chirps will be heard.
2. Enter the user ID to clear, followed by ENTER (3 chirps will be heard).
3. Press 3 3 5, # (3 chirps are heard) (335 = DEL).
4. Enter the user ID to clear, followed by ENTER (2 chirps will be heard).
5. Press 3 3 5, # (5 chirps are heard).
The code assigned to that user ID has been deleted. If an error is encountered, the control will beep
continuously for 3 seconds. The Master Code stored in user ID 99 cannot be deleted.
Example: To delete the user code in ID 15:
1. Press 3 6 5 # 1 2 3 4 5 6 [ENTER] (5 chirps will be heard).
2. Press 1 5 [ENTER] (3 Chirps will be heard).
3. Press 3 3 5, # (3 Chirps will be heard) (335 = DEL).
4. Press 1 5 [ENTER] (2 Chirps will be heard).
5. Press 3 3 5, # (5 Chirps will be heard).