EasyManua.ls Logo

Fondital PANAREA COMPACT - ERP and Labelling Data; No. 5 Chart - ERP and Labelling Data

Fondital PANAREA COMPACT
32 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
14
Item Symbol Value Unit Item Symbol Value Unit
Rated heat output
P
n
22 kW
Seasonal space heating energy
efficiency
η
S
78 %
At rated heat output and high-
temperature regime (*)
P
4
22,2 kW
At rated heat output and high-
temperature regime (*)
η
4
81,6 %
At 30 % of rated heat output and low-
temperature regime (**)
P
1
6,0 kW
At 30 % of rated heat output and low-
temperature regime (**)
η
1
81,1 %
At full load
el
max
0,012 kW Standby heat loss
P
stby
0,103 kW
At part load
el
min
0,011 kW Ignition burner power consumption
P
ign
0,000 kW
In standby mode
P
SB
0,002 kW Annual energy consumption
Q
HE
82 GJ
Emissions of nitrogen oxides
NO
x
141 mg/kWh
Daily electricity consumption
Q
elec
0,038 kWh Daily fuel consumption
Q
fuel
25,370 kWh
Annual electricity consumption AEC 8 kWh Annual fuel consumption AFC 19 GJ
C
B
Seasonal space heating energy efficiency class
Water heating energy efficiency class
For combination heaters:
Model(s): PANAREA COMPACT CTN 24 AF
Condensing boiler: no
Low-temperature (**) boiler: no
B1 boiler: yes
Cogeneration space heater: no If yes, equipped with a supplementary heater: -
Combination heater: yes
For boiler space heaters and boiler combination heaters:
Useful heat output
For boiler space heaters and boiler combination heaters:
Useful efficiency
Auxiliary electricity consumption Other items
%
(*) High-temperature regime means 60 °C return temperature at heater inlet and 80 °C feed temperature at heater outlet.
(**) Low temperature means for condensing boilers 30 °C, for low-temperature boilers 37 °C and for other heaters 50 °C return temperature (at heater inlet).
75
Contact details: FONDITAL S.p.A. - Via Cerreto, 40 I-25079 VOBARNO (Brescia) Italia - Italy
Declared load profile XL Water heating energy efficiency
η
wh
2.6. ERP and Labelling data