Startup Problems
ReferenceRemedyPossible causeSymptom
-Connect the system
to the mains.
System not
connected to mains.
The system
cannot be started
after switching
on.
-Switch the system
on.
You switched off the
system accidentally.
-Press the power
button next to the
touch screen.
You did not press the
power button next to
the touch screen.
-Close the covers.A cover is opened.
Envelope Sealing Problems
ReferenceRemedyPossible causeSymptom
See symptom “Flap
not
sufficiently
moistened.”.
-Insufficient
moistening.
Envelope not
closed properly.
“Job Programming”Make sure if the job
is programmed to
seal envelopes.
The current job has
no envelope sealing.
-Make sure the
document size and
enclosure size equals
the job settings.
Document or
enclosure not
compliant with job
specification.
“Adjusting the Side
Guides of the Docu-
ment
Feeder”.
Make sure the side
guides of the
document feeders
are in the correct
position.
Documents are not
correctly inserted.
“Envelope Position”Check envelope stop
position, adjust if
needed.