Turning off FortiGate-4000 chassis power
Always shut down the FortiGate-4000 operating system properly before turning off the
power switch. Turn off the FortiGate-4000 chassis power in the reverse order from
turning power on.
1 From the web-based manager, go to System > Maintenance > ShutDown, select
Shut Down and select Apply, or from the CLI, enter:
execute shutdown
2 Press the power button on each FortiBlade-4010 module.
The PWR LED on each FortiBlade-4010 module goes out.
3 Turn off the switched interface module power switch for each switched interface
module (FortiGate-4000S).
4 Turn off the management module power switch.
5 Turn off the chassis power switch.
6 Turn off the power switch on each power supply module.
Hot swapping modules
This section describes how to hot swap the modules installed in the FortiGate-4000
chassis. Hot swapping refers to removing a failed module and replacing it with a new
version of the same module while the FortiGate-4000 chassis remains in operation.
This section describes:
Hot swapping FortiBlade-4010 modules
Hot swapping cooling fan trays
Hot swapping power supplies
Hot swapping interface modules
Hot swapping the 10/100 out of band management module
Hot swapping the management module
Hot swapping the KVM switch module
Hot swapping FortiBlade-4010 modules
Follow this procedure to hot swap the FortiBlade-4010 modules. For information about
the FortiBlade-4010 module, see “FortiBlade-4010 module” on page 17.
1 Press the power button on the front panel of the FortiBlade-4010 module that you
want to replace.
The PWR LED on the FortiBlade-4010 module goes out.
Note: Always wait at least five seconds after turning off FortiGate-4000 chassis power before
turning it back on. Turning the power on and off in rapid succession can damage
FortiGate-4000 electrical circuitry.
Note: Wait at least five seconds after turning off the power before removing the FortiBlade-4010