Hardware Specifications
September 2007 © 2007 Foundry Networks, Inc. 2 - 13
Mean Time Before Failure
Table 0.19 provides the intitial MTBF result for the RPS2-EIF (including the Power Supply Unit).
Electrical Specifications
This section lists the electrical specifications for the power supply.
Input specifications
Operating temperature 32° to 110° F, 0 ° to 45° C
Operating relative
humidity
5 – 95%, non-condensing
Operating altitude up to 6,600 feet above sea level
Storage temperature -40° to 158° F, - 4 0 ° to +70° C
Storage altitude up to 15,000 feet above sea level
Cooling internal fan, 28 mm, 9500rpm
Table 0.19: Mean Time Before Failure Specifiations
Platform Temperature System Failure Rate System MTBF
RPS2-EIF 25° C (76.9° F) 7343.584745 136,173
50° C (121.9° F) 17,129.130581 58,380
Table 0.20: Input Specifications for Power Supplies
Property RPS2-EIF
Input voltage range 100 - 240 VAC
Input current < 10 Amps
Inrush current 60 A
Table 0.18: Environmental Considerations for Power Supplies

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Foundry Networks FastIron LS 624 and is the answer not in the manual?

Foundry Networks FastIron LS 624 Specifications

General IconGeneral
BrandFoundry Networks
ModelFastIron LS 624
CategorySwitch
LanguageEnglish

Related product manuals