EasyManuals Logo

Foxconn H77MXV Series User Manual

Foxconn H77MXV Series
103 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #99 background imageLoading...
Page #99 background image
RAID CONFIGURATION
92
4.Press<Space>keytoselectitandpress<Enter>,itreturnstothemainmenu.Youcansee
the74.5GBdiskisofine,andactionsofRecoverychangefromContiousUpdatemodeto
On-Request.
Intel(R)MatrixStorageManageroptionROMv5.0.0.1011ICH9RwRAID5
Copyright(C)2003-04IntelCorporationAllRightsReserved.
1. Create RAID Volume
2.DeleteRAIDVolume 5.AccelerationOptions
3. Reset Disks to Non-RAID 6. Exit
RAID Volume :
ID Name Level Stripe Size Status Bootable
0 TryRecovery Recovery(OnReq)N/A 74.5GB NeedUpdate Yes
Physical Disks:
Port Drive Model Serial # Size Type/Status(Vol ID)
0 HitachiHDS72161 PVF904Z21G2JZM 149.0GB Recovery Disk(0)
1
ST380811AS
5PS1TAGW 74.5GB Offline Disk(0)
2
SAMSUNG HD161HJ
S0V3J9APA30524 149.0GB Member Disk(0)
3
ST380815AS
5RW1CA37
74.5GB Non-RAID Disk
Intel(R)RapidStorageTechnology-UptionROM-11.0.8.1204
Copyright(C)2003-11IntelCorporation.AllRightsReserved.
[DISK/VOLUMEINFORMATION ]
[ MAIN MENU ]
[↑↓]-Select[ESC]-Exit[ENTER]-SelectMenu
4.RecoveryVolumeOptions
6. Exit RAID BIOS
1.TakeTryRAID5asanexample,select“5.Exit”inmainmenuandpress<Enter>.Thescreen
displays:
Intel(R)MatrixStorageManageroptionROMv5.0.0.1011ICH9RwRAID5
Copyright(C)2003-04IntelCorporationAllRightsReserved.
1.CreateRAIDVolume 4.RecoverVolumeOptions
2.DeleteRAIDVolume 5.AccelerationOption
3. Reset Disks to Non-RAID
RAID Volume :
ID Name Level Stripe Size Status Bootable
0 TryRAID5 RAID5(Parity)64KB 149.1GB Normal Yes
Physical Disks:
Port Drive Model Serial # Size Type/Status(Vol ID)
0 HitachiHDS72161 PVF904Z21G2JZM 149.0GB Member Disk(0)
1
ST380811AS
5PS1TAGW 74.5GB Member Disk(0)
2
SAMSUNG HD161HJ
S0V3J9APA30524 149.0GB Member Disk(0)
3
ST380815AS
5RW1CA37
74.5GB Non-RAID Disk
Intel(R)RapidStorageTechnology-UptionROM-11.0.8.1204
Copyright(C)2003-11IntelCorporation.AllRightsReserved.
[DISK/VOLUMEINFORMATION ]
[ MAIN MENU ]
6. Exit
[↑↓]-Select[ESC]-Exit[ENTER]-SelectMenu
Are you sure you want to exit? (Y/N):
[ CONFIRM EXIT ]
2.Press<Y>toexitIntel®RapidStorageTechnologyenterpriseprogram.Thesystemwillenter
BIOS setup.
3. Shut down the computer, remove the Non-RAID disk, and we will continue for Windows OS
installation. If you do not remove irrelevant hard disk, Windows may detect it during the
installation, and you could be confused.
4.Removeanydiskettefromoppydrive.
5.RestartcomputertostartWindowsinstallation.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Foxconn H77MXV Series and is the answer not in the manual?

Foxconn H77MXV Series Specifications

General IconGeneral
BrandFoxconn
ModelH77MXV Series
CategoryMotherboard
LanguageEnglish

Related product manuals