Page 13
Evolution Plus technical data
Coee bean hopper 1.3 kg per grinder (optional: lockable)
Grounds container 50 cakes (optional: grounds ejection)
Boiler volume small boiler: coee 1.2 l 1.0 MPa (145 psi)
large boiler: hot water/steam 1.6 l 0.2 MPa (29 psi)
Electrical connection 200 V 3 L PE 4 kW 50/60 Hz Fuse: 20 A
200 - 208 V 1 L N PE 2.6 kW 50/60 Hz Fuse: 16 A
230 - 240 V 1 L N PE 3.2 kW 50/60 Hz Fuse: 16 A
230 - 240 V 1 L N PE 5.2 kW 50/60 Hz Fuse: 30 A
380 V 2 L N PE 5.2 kW 50/60 Hz Fuse: 16 A
400 V 2 L N PE 5.2 kW 50/60 Hz Fuse: 16 A
208 V 2 Ph PE 4.8 kW 50/60 Hz Fuse: 30 A Current: 24 A
Electric cable l = 1800 mm (70.86")
Supply line Metal hose with union nut G3/8", l = 1500 mm (59")
Waste-water hose d = 16 mm (0.63"), l = 2000 mm (75.75")
not permanently attached to the drain (vented)
Noise emission < 70 dB (A)
Weight 1M 46 kg 2M 50 kg
Cold water connection G3/8” outside thread
Water pressure 80 - 800 kPa (0.8 - 8.0 bar or 11.6 - 116 psi)
Water shut-o with check valve and lter
Water hardness max. 70 mg CaO/1 l water (7 dH, 13 °fH)
Chlorine content max. 0.1 mg/l (0.1 ppm)
Ideal pH value 7
Funnel d = 50 mm (1.97") with siphon
Drain pipe dmin = 1"
Ambient conditions Humidity: max. 80 %
Ambient temperature: 10 - 35 °C (50 - 95 °F)
Preparations
• The power connection for the coee machine must be protec-
ted by a ground fault circuit interrupter (GFCI).
• Each terminal of the power supply must be able to be interrup-
ted by a switch.
• The water connection must have a shut-o with a check valve
and lter and must meet the requirements of the technical data.
• The water for the preparation of coee should always be fresh,
oxygenated and rich in minerals.
• If your Evolution Plus has an electrical connection other than
the one described in the table opposite, you will have received
additional information regarding the installation with your order
conrmation.
Installation
You must have completed these preparations before one of our
service technicians can install Evolution Plus for you.
One of our service technicians will install your Evolution Plus and
put them into operation for the rst time. The technician will walk
you through the basic functions.
Your Evolution Plus must be properly installed so that you can operate it correctly—one of our service technicians will
do that for you. You'll have to take care of a few things rst. You'll nd the preparations for problem-free enjoyment of
your coee machine here
Installation and technical data
Installation

Related product manuals