FP4000 Rev0204
18
OPERATION
On power-up the pressure gauge/flowmeter will be in the normal operating mode.
Pressure and flow rate information from a transducer and a flow sensor or from the
datalink interface is processed and displayed. Operator input is necessary only when
using the totalizing function (with the optional external button) or accessing program
information.
Datalink Interface
The FRC datalink interface is standard on all pressure gauge/flowmeters and
provides a way of connecting multiple display modules on a shared data bus. The
FP4000 (pressure gauge/flowmeter) and DF4000 (digital flowmeter) series display
modules can operate as independent displays or they can be interconnected to provide
remote displays, the display of flow through multiple discharges (summing), and the
display of total flow for multiple discharges (accumulation). (Refer to Figure 7.)
Note: The FP4000 series can only be used as a primary or remote display
module.
Primary Display Module
Primary displays are programmed with the module function Pri. A primary display
receives input from the pressure transducer and flow sensor. When it is programmed
with Id 0 it will not output information on to the datalink. When it is programmed with
Id 1 to Id 99, it will provide information (via the datalink) to remote, summing, and
accumulator displays.
Remote Display Module
Remote displays are programmed with the module function SLA (slaved to a
primary). A remote display must be programmed with the same ID number as a primary
display. It will receive information for the display of pressure and flow rate from the
primary display over the datalink. All program code features are programmed
independently of the primary display. No calibration is necessary on a remote display.
Summing Display Module
Summing displays are programmed with the module function SU. A summing
display will show the actual flow rate for all primary displays on the datalink except
for those with Id 0. (Available on the DF4000 series only.)
Accumulator Display Module
Accumulator displays are programmed with the module function ACC. An
accumulator display will show total accumulated flow for all primary displays on the
datalink except for those with Id 0. The number shown in the display will be x 100
scale. (Available on the DF4000 series only.)