4
General Specications
Model Identication Guide
Electric Heater Size
A Series
25 = 2.5 KW
34 = 3.4 KW
50 = 5.0 KW
75 = 7.5 KW*
10 = 10.0KW**
MODEL NUMBER V H A 09 K 34 RT Q
Marketing Revision
Options
RT = Standard Remote Operation
Voltage
K = 208/230V-1Ph-60Hz
R = 265V-1Ph-60Hz
Nominal Capacity
09 = 9,000 Btu/hr 18 = 18,000 Btu/hr
12 = 12,000 Btu/hr 24 = 24,000 Btu/hr
Series
V = Friedrich Vertical Series
* ONLY AVAILABLE ON THE 18 & 24 K/R MODELS
**ONLY AVAILABLE ON THE 24 K/R MODELS
HA = Air-Source Heat Pump
MODEL
VHA09K VHA09R VHA12K VHA12R VHA18K VHA18R VHA24K VHA24R
COOLING DATA
TOTAL COOLING CAP. (Btu/hr) @95°F
9,000 8,800 11,000 11,000 17,600 17,400 21,800 21,600
SENSIBLE COOLING CAP. (Btu/hr)
6,650 6,650 8,100 8,100 12,500 12,500 15,400 15,000
SEER2
11.9 11.9 11.9 11.9 11.9 11.9 11.9 11.9
EER2
10.6 10.6 10.6 10.6 10.6 10.6 10.6 10.6
VOLTAGE
208/230 265 208/230 265 208/230 265 208/230 265
HEATING DATA
HEAT PUMP CAP. (Btu/hr) @ 47°F
8,200 8,200 10,400 10,400 16,000 16,000 18,500 18,500
HEAT PUMP CAP. (Btu/hr) @ 17°F
4,500 4,500 5,600 5,600 9,000 9,000 12,000 12,000
COP
3.1 3.1 3.1 3.1 3.1 3.1 3.1 3.1
HSPF2
6.3 6.3 6.3 6.3 6.3 6.3 6.3 6.3
HEATER SIZE (kW)
2.5/3.4/5.0 2.5/3.4/5.0 2.5/3.4/5.0 2.5/3.4/5.0 2.5/3.4/5.0/7.5 2.5/3.4/5.0/7.5 2.5/3.4/5.0/7.5/10.0 2.5/3.4/5.0/7.5/10.0
PHYSICAL
DIMENSIONS (W X D X H)
23”x23”x32” 23”x23”x32” 23”x23”x32” 23”x23”x32” 23”x23”x47” 23”x23”x47” 23”x23”x52” 23”x23”x52”
REFRIGERANT
R410a
VENTILATION AIR
CFM
UPTO 60
NOTE: Due to continuing research in new energy-saving technology, specications are subject to change without notice.