135
Checks to perform:
Checks to perform:
Checks to perform:
E93
E93: Software Configuration error
E93
Wrong MCF data loaded
WARNING
Check that all the connectors are correctly inserted
Replace the Electronic Control Board and repeat the Diagnostic Cycle to check for any further alarms.
E94
E94: Software Configuration error
E94
Microprocessor corrupted
WARNING
Check that all the connectors are correctly inserted
Replace the Electronic Control Board and repeat the Diagnostic Cycle to check for any further alarms.
E97
E97: Software Configuration
E97
Wrong MCF data loaded cycle selector switch failure.
WARNING
Check that all the connectors are correctly inserted
Replace Cycle Selector Switch and retry if the problem still exists, replace the Electronic Control Board and repeat the
Diagnostic Cycle to check for any further alarms.