E11
E11: Difficulties in water fill for washing
E11
Water tap closed, water flow rate too low, pressure sensor defective, Water inlet
valve defective, Wrong drain pipe position (siphon), Water leak, wiring or Main
Board.
Checks to perform:
Run the Diagnostic Cycle test and check if hot and cold inlet valves are working?
WARNING
Check that all the connectors are correctly inserted
Is the drain pipe positioned correctly and not
causing the siphon effect? (See Fig.1)
Are the washing machine’s water lines efficient
(leaking)?
Is the pressure sensor air tube connected properly
(check also for kinking and leaking)? (Disconnect
the tube and blow to ensure no obstruction)
Is the wiring connection on the pressure sensor
connected properly?
Is the frequency of pressure sensor between 45
Hz to 45.5 Hz? (Measure it on the pressure sensor
wiring connector at Main Control Board when
machine is powered with empty tub (No water))
(See Fig.2)
Replace the Main Control Board and repeat the Diagnostic Cycle to check for any further alarms
See Next
Page
Repair the drain circuit and repeat the Diagnostic Cycle
to check for any further alarms.
Repair the water circuit and repeat the Diagnostic Cycle
to check for any further alarms.
Repair the air tube on the Pressure Sensor and repeat
the Diagnostic Cycle to check for any further alarms.
Replace / Repair the wiring and repeat the Diagnostic
Cycle to check for any further alarms.
Replace the Pressure Sensor and repeat the Diagnostic
Cycle to check for any further alarms.
Y
E
S
Y
E
S
Y
E
S
Y
E
S
Y
E
S
NO
NO
NO
NO
NO
Y
E
S
N
O