EasyManua.ls Logo

Frigoboat MS SERIES - 8. Troubleshooting; 8.1 Troubleshooting

Frigoboat MS SERIES
28 pages
Print Icon
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Page
27
8. TROUBLESHOOTING
Fridges & Freezers Boxes
SERIE MS
STAINLESS STEEL
Series
8.1 Troubleshooting
Before calling an Authorized Assist ance Centre , we suggest some checks to solve the most common cases of bad func -
tioning, not directly caused by material defect s or inst allation errors.
If the system wouldn t work af ter having checked it, call the nearest Frigoboat
Authorized Assist ance Centre
.
To have some information about the nearest Authorized Assist ance Centre, call the V e c o service ( +39.0362.35321) or go
to the WEB page w w w.frigoboat.it
NOTE:
W ait one minute: there is up to one minute delay between the power ON and the compressor st arting. Allow enough time.
8.1 - THE BOX IS TO O COLD OR THE COMPRESSOR RUNS CONTINUOSLY
8.1.1 - T urn the thermost at clockwise towards 1 . If the box is still too cold with thermost at set at 1 , then stop the com -
pressor, putting the thermost at to 0 or switching of f the fridge switch. Use this switch to make run the compressor for 15
minutes every 1 - 3 hours to keep the box at the normal temperature (+2 / -6 ). The unit must be checked by a Frigoboat
Authorized Service.
8.2 - THE BOX IS NOT COLD ENOUGH A LTHOUGH THE COMPRESSOR RUNS NORMALLY
8.2.1 - Remove any warm food from the box and let it cool down to ambient temperature before storing it again.
8.2.2 - The door must be perfectly closed and the door gasket s must fit perfectly . Nothing must prevent the door gasket
to seal.
8.2.3 - Check that there are no obstructions in the compressor air int ake and outlet and the condenser is clean.
8.2.4 - When the compressor is running, the fan should run in air-cooled models and the pump should run and the water
flow in W models. Otherwise it is necessary to clean the filter .
8.3 - THE COMPRESSOR STARTS BUT STOPS ALMOST IMMEDIATELY AFTERW ARDS
8.3.1 - Check the battery charge. If necessary, charge the battery.
8.3.2 - Check that all the connections and the fuse of the battery supply to the Frigomatic are well tightened and not cor -
roded. In winter the compressor temperature should be above 0 C.
8.3.3 - Disconnect the F terminal from the electronic control. If the compressor runs correctly, check the fan, the pump
or the pump relay as the amperage is too high. As soon as you can, the unit shoul be checked by a Frigoboat Authorized
Assist ance Centre.
8.4 - THE COMPRESSOR DOESN T STA R T
8.4.1 - There is a delay between the power ON and the compressor st arting. W ait one minute.
8.4.2 - On the electronic control check that the + and - volt age is 12 V (24 V) and the thermost at has been set on 7 .

Related product manuals