IT O Y L O R ^ y (S ^ F R K io m a r
"MEB^" (**) BOARD PROGRAM MING TABLE
P
DESCRIPTION
MIN
MAX
C122 C119
STEP
P1
Machine model 0
7 6
5
C119=5
C l22=6
P2
Slush coefficient
10 40
15 15
1
P3
Consistency hysteresis
(%of setting)
1
50
10 10
1
P4
Voltage and frequency
selection
0 2
*
*
0= 115-230/50-60/1
1=400-440/50-60/3
2= 220/230/50-60/3 (without
neutral)
P5
Sampling 1 SET OK
(AUTO cycle minimum
threshold)
50
200 150 150
1
P6
Sampling 1 Time
(AUTO cycle)
0 22 10
10
4,5,6,7,8,9,10,11,12,13,14,15,16,1
7,18,20,22 sec.
P7
Sampling 2 SET OK
(AUTO cycle average
threshold)
50 200 190
190 1
P8
Sampling 2 Time
(AUTO cycle)
0
22 4
4
4,5,6,7,8,9,10,11,12,13,14;15,16,1
7,18,20,22 sec.
P9
Sampling 3 SET OK
(AUTO HARD cycle minimum
threshold)
50 200 180
180
1
P10
Sampling 3 Time
(AUTO HARD cycle)
0
22 14 14
4.5,6,7,8,9,10,11,12,13,14,15,16,1
7,18,20,22 sec.
P11
Sampling 4 SET OK
(AUTO HARD cycle average
threshold)
50
200 200 200
1
P12
Sampling 4 Time
(AUTO HARD cycle)
0
22 10 10
4,5,6,7,8,9,10,11,12,13,14,15,16,1
7,18,20,22 sec.
P13
Not active
P14
Beater ON time in Cyclic
Slush mode
P15
Not active
P16
Not active
P17
Not active
ENGLISH - 34