The Setup menu
Accessing the
Setup menu
Use the welding process button to select the process for which the Setup param-
eters are to be changed:
MMA welding
MMA welding with Cel electrode
TIG welding
+ Press the setting value and welding process buttons together
After releasing the buttons, the code for the first parameter in the Setup menu is
displayed
Changing weld-
ing parameters
Turn the adjusting dial to select the required parameter
Press the adjusting dial to display the preset value of the parameter
Turn the adjusting dial to change the value
The new value becomes effective immediately
Exception: when restoring the factory settings, press the adjusting dial after
changing the value to activate the new value.
Press the adjusting dial to return to the list of parameters
Exiting the Setup
menu
Press the setting value or
welding process button to exit the Setup menu
Parameters for
MMA welding
1
2
1
2
3
4
1
Parameter Description Range Unit
Starting current duration
For the SoftStart / HotStart function
Factory setting: 0.5 seconds
0.1 - 1.5 Seconds
Anti-stick
When the anti-stick function is active, the arc is
extinguished after 1.5 seconds in the event of a
short circuit (sticking of the electrode)
Factory setting: ON (activated)
On
OFF