EasyManua.ls Logo

Fronius AccuPocket 150/400 TIG - No Function

Fronius AccuPocket 150/400 TIG
84 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
59
EN
No function The power source cannot be switched on
Cause: The battery has entered a state of deep discharge as it has been stored for
too long without being charged
Remedy: Charge the battery now
Battery operation is possible again above 25% capacity.
If charging is no longer possible, contact After-Sales Service.
Cause: Control panel defective
Remedy: Contact After-Sales Service
Battery is not charged
Power source is connected to the charger, charger is connected to the mains, no charging
indicator on the power source
Cause: Device is too hot
Remedy: Check/reduce ambient temperature, allow battery to cool down
Cause: Device temperature too low
Remedy: Check/increase ambient temperature
No welding current
Power source is switched on, indicator for the selected welding process is lit
Cause: Welding power-lead connections have been disconnected
Remedy: Establish proper welding power-lead connections
Cause: Poor or no earth
Remedy: Establish a connection to the workpiece
Cause: There is a break in the power cable in the welding torch or electrode holder
Remedy: Replace welding torch or electrode holder
No welding current
Power source is switched on, indicator for the selected welding process is lit, overtemper-
ature indicator lit
Cause: Duty cycle exceeded - power source overloaded - fan running
Remedy: Keep within duty cycle
Cause: Thermostatic automatic circuit breaker has been tripped
Remedy: Wait until the power source comes back on automatically at the end of the
cooling phase
Cause: The fan in the power source is faulty
Remedy: Contact After-Sales Service
Cause: Insufficient cooling air intake
Remedy: Ensure adequate air supply
Cause: Air filter is dirty
Remedy: Clean air filter

Table of Contents