51
EN
Parameters for
TIG welding
Break voltage (U cut off)
Used to specify at which arc length the welding
process is to be completed.
The welding voltage increases as the length of the
arc increases. The arc is extinguished when it
reaches the voltage specified here.
Factory setting: 45 volts
25 - 80 Volts
Software version
The full version number of the currently installed
software is spread across a number of displays
and can be retrieved by turning the adjusting dial.
Automatic switch-off (time Shut down)
If the power source is not operated for the speci-
fied length of time, it switches off automatically.
Factory setting: 900 seconds
300 - 900
OFF
Seconds
Factory setting (FACtory)
The power source can be reset to its factory set-
tings here.
- Cancel reset no
- Reset the parameters for the selected weld-
ing process to their factory settings
YES
- Reset the parameters for all welding process-
es to their factory settings
ALL
Resetting of the selected value to its factory set-
ting must be confirmed by pressing the adjusting
dial.
Parameter Description Range Unit
Parameter Description Range Unit
Operating mode (trigger mode)
- Operation using welding torch without a torch
trigger
- 2-step mode
- 4-step mode
Factory setting: 2-step
OFF
2-step
4-step
Starting current (I-Start)
This parameter is only available in 4-step mode
(tri = 4-step).
Factory setting: 50%
1 - 200 Percent
Reduced current
This parameter is only available in 4-step mode
(tri = 4-step).
Factory setting: 50%
1 - 200 Percent