Fronius ActiveCharger 1000 - Operating Modes

Fronius ActiveCharger 1000
72 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
65
EN
Operating modes Charging
Starts automatically when the battery charger is connected to the power source and the
mains
- The CHARGING indicator is lit
- Mains indicator lit
- The power source is charged at optimum charging power
- The charging characteristic of this mode maximises the service life of the power
source
- When the COMPLETED indicator lights up, the power source is fully charged
and the battery charger switches to conservation charging mode
Quick charging
Activation:
Press the QUICK CHARGING button
- The QUICK CHARGING indicator is lit
- Mains indicator lit
- The power source is charged at the maximum possible charging power
- When the COMPLETED indicator lights up, the power source is fully charged
and the battery charger switches to conservation charging mode
Deactivation:
Press the QUICK CHARGING button again
- Charging mode resumes
Conservation charging
Starts automatically once the battery charger has fully charged the power source
- Mains indicator lit
- The COMPLETED indicator is lit
- The power source is charged at conservation charging power
- In this mode, the power source can remain connected to the charger without being
damaged.
Hybrid mode
= the battery charger is charging the power source while the power source is in operation
Acivation:
Start welding during charging
or connect the power source to the charger while it is in operation
- The QUICK CHARGING indicator is lit (charging at the maximum possible
charging power in hybrid mode)
- Mains indicator lit
- The power source is discharged according to its operating load and simultaneously re-
charged by the charger