45
EN
Break voltage (U cut off)
25 - 80 Volts
Used to specify at which arc length the welding process is to be completed.
The welding voltage increases as the length of the arc increases. The arc is extinguished
when it reaches the voltage specified here.
Factory setting: 45 volts
Software version
The full version number of the currently installed software is spread across a number of
displays and can be retrieved by turning the adjusting dial.
Automatic switch-off (time Shut down)
300 - 900 Seconds / OFF
If the power source is not operated for the specified length of time, it switches off automat-
ically.
Factory setting: 900 seconds
Factory setting (FACtory)
The power source can be reset to its factory settings here.
no / YES / ALL
- Cancel reset
- Reset the parameters for the selected welding process to their factory settings
- Reset the parameters for all welding processes to their factory settings
Resetting of the selected value to its factory setting must be confirmed by pressing
the adjusting dial.
Parameters for
TIG welding
Comfort Stop Sensitivity
0.3 - 2.0 Volts / OFF
Factory setting: 0.5
For details see the External Link: “” section on page External Link: “”
Break voltage (U cut off)
12 - 35 Volts
Used to specify at which arc length the welding process is to be completed. The welding
voltage increases as the length of the arc increases. The arc is extinguished when it reach-
es the voltage specified here.
This parameter is only available when the CSS parameter is set to OFF.
Factory setting: 15 volts