Cause: At maximum wire feed speed,
the motor of the push-pull unit
does not deliver any actual rota-
tional speed value.
Remedy: Repeat the push-pull calibra-
tion. If the error message re-
appears: Contact After-Sales
Service.
Cause: Push-pull calibration was inter-
rupted: Quick-stop was activ-
ated by pressing the torch trig-
ger.
Remedy: Repeat push-pull calibration
Service codes when the drive units are engaged (engaged calibration)
Cause: "Push-pull calibration - open-cir-
cuit" has not been carried out
Remedy: Carry out "push-pull calibration -
open-circuit"
Cause: At minimum wire feed speed,
the wire-feed unit motor does
not deliver any actual rotational
speed value.
Remedy: Repeat the push-pull calibra-
tion. If the error message re-
appears: Contact After-Sales
Service.
Cause: At minimum wire feed speed,
the motor of the push-pull unit
does not deliver any actual rota-
tional speed value.
Remedy: Repeat the push-pull calibra-
tion. If the error message re-
appears: Contact After-Sales
Service.
130

Table of Contents

Other manuals for Fronius MagicWave 3000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fronius MagicWave 3000 and is the answer not in the manual?

Fronius MagicWave 3000 Specifications

General IconGeneral
BrandFronius
ModelMagicWave 3000
CategoryPortable Generator
LanguageEnglish

Related product manuals