Mark of conformity S, CE
Idle state power consumption at 400 V 50.0 W
Power source efficiency at 300 A / 32.0 V 84%
MagicWave 2500
Comfort MV
Mains voltage 3 x 200 - 240 V
3 x 400 - 460 V
1 x 200 - 240 V
Mains voltage tolerance ± 10%
Grid frequency 50/60 Hz
Mains fuse protection (slow-blow)
3 x 400 - 460 V
3 x 200 - 240 V
1 x 200 - 240 V
16 A
32 A
32 A
Mains connection
1)
Z
max
on PCC
3)
= 122 mOhm
Primary continuous power (100% D.C.
2)
)
3 x 400 - 460 V
3 x 200 - 240 V
1 x 200 - 240 V
4.8 kVA
4.4 kVA
3.9 kVA
Cos phi 0.99
Welding current range (3-phase)
TIG 3 - 250 A
Electrode 10 - 250 A
Welding current range (single phase)
TIG 3 - 220 A
Electrode 10 - 180 A
Welding current at 3 x 400 - 460 V
10 min/40 °C (104 °F) 35% D.C.
2)
-
10 min/40 °C (104 °F) 40% D.C.
2)
250 A
10 min/40 °C (104 °F) 100% D.C.
2)
180 A
Welding current at 3 x 200 - 240 V
10 min/40 °C (104 °F) 30% D.C.
2)
-
10 min/40 °C (104 °F) 35% D.C.
2)
250 A
10 min/40 °C (104 °F) 100% D.C.
2)
160 A
Welding current at 1 x 200 - 240 V
10 min/40 °C (104 °F) 40% D.C.
2)
220 A
10 min/40 °C (104 °F) 50% D.C.
2)
-
10 min/40 °C (104 °F) 100% D.C.
2)
150 A
Open circuit voltage 89 V
201