EasyManua.ls Logo

Fronius MagicWave 3000

Fronius MagicWave 3000
220 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Mark of conformity S, CE
Idle state power consumption at 400 V 50.0 W
Power source efficiency at 300 A / 32.0 V 84%
MagicWave 2500
Comfort MV
Mains voltage 3 x 200 - 240 V
3 x 400 - 460 V
1 x 200 - 240 V
Mains voltage tolerance ± 10%
Grid frequency 50/60 Hz
Mains fuse protection (slow-blow)
3 x 400 - 460 V
3 x 200 - 240 V
1 x 200 - 240 V
16 A
32 A
32 A
Mains connection
1)
Z
max
on PCC
3)
= 122 mOhm
Primary continuous power (100% D.C.
2)
)
3 x 400 - 460 V
3 x 200 - 240 V
1 x 200 - 240 V
4.8 kVA
4.4 kVA
3.9 kVA
Cos phi 0.99
Welding current range (3-phase)
TIG 3 - 250 A
Electrode 10 - 250 A
Welding current range (single phase)
TIG 3 - 220 A
Electrode 10 - 180 A
Welding current at 3 x 400 - 460 V
10 min/40 °C (104 °F) 35% D.C.
2)
-
10 min/40 °C (104 °F) 40% D.C.
2)
250 A
10 min/40 °C (104 °F) 100% D.C.
2)
180 A
Welding current at 3 x 200 - 240 V
10 min/40 °C (104 °F) 30% D.C.
2)
-
10 min/40 °C (104 °F) 35% D.C.
2)
250 A
10 min/40 °C (104 °F) 100% D.C.
2)
160 A
Welding current at 1 x 200 - 240 V
10 min/40 °C (104 °F) 40% D.C.
2)
220 A
10 min/40 °C (104 °F) 50% D.C.
2)
-
10 min/40 °C (104 °F) 100% D.C.
2)
150 A
Open circuit voltage 89 V
201