Care, maintenance and disposal
General Under normal operating conditions, the power source requires only a minimum of care
and maintenance. However, it is vital to observe some important points to ensure it
remains in a usable condition for many years.
Safety
WARNING!
Work that is carried out incorrectly may result in serious injury or damage to prop-
erty.
▶
All the work described below must only be carried out by trained and qualified per-
sonnel.
▶
Do not carry out any of the work described below until you have fully read and
understood this document.
▶
Do not carry out any of the work described below until you have fully read and
understood all of the documents relating to the system components, in particular the
safety rules.
WARNING!
An electric shock can be fatal.
Before starting the work described below:
▶
Turn the power source mains switch to the "O" position
▶
Disconnect the power source from the grid
▶
Ensure that the power source remains disconnected from the mains until all work
has been completed
▶
After opening the device, use a suitable measuring instrument to check that electric-
ally charged components (e.g. capacitors) have been discharged.
WARNING!
An inadequate ground conductor connection can cause serious injury or damage.
The housing screws provide a suitable ground conductor connection for earthing the
housing.
▶
The housing screws must never be replaced with different screws unless a reliable
ground conductor connection is established.
At every start-up - Check mains plug, mains cable, welding torch, interconnecting hosepack and
ground earth connection for damage
- Check that the device has an all-round clearance of 0.5 m (1 ft. 8 in.) to ensure that
cooling air can flow in and out freely
NOTE!
The air inlets and outlets must never be covered, not even partially.
Every 2 months - If present: clean air filter
193