EasyManua.ls Logo

Fronius MagicWave 3000

Fronius MagicWave 3000
220 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Cause: At maximum wire feed speed,
the motor current of the wire-
feed unit motor is outside the
permitted range. Possible reas-
ons are disengaged wire-feed
unit motors or wire feed prob-
lems.
Remedy: Engage the drive units of both wire-feed unit motors, arrange the hosep-
ack in as straight a line as possible; check the inner liner for kinks or soil-
ing; check the contact pressure on the 2-roller or 4-roller drive of the
push-pull unit. Repeat the push-pull calibration. If the error message re-
appears: Contact After-Sales Service.
Cause: At maximum wire feed speed,
the motor current of the push-
pull unit is outside the permitted
range. Possible reasons are
disengaged wire-feed unit
motors or wire feed problems.
Remedy: Engage the drive units of both wire-feed unit motors, arrange the hosep-
ack in as straight a line as possible; check the inner liner for kinks or soil-
ing; check the contact pressure on the 2-roller or 4-roller drive of the
push-pull unit. Repeat the push-pull calibration. If the error message re-
appears: Contact After-Sales Service.
Cause: Push-pull calibration was inter-
rupted: Quick-stop was activ-
ated by pressing the torch trig-
ger.
Remedy: Repeat push-pull calibration
132

Table of Contents

Other manuals for Fronius MagicWave 3000

Related product manuals