EasyManua.ls Logo

Fronius MagicWave 3000

Fronius MagicWave 3000
220 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Cause: Mains undervoltage: The mains
voltage has dropped below the
lower limit of the tolerance
range (see section "Technical
data")
Remedy: Check the mains voltage
Cause: Mains overvoltage: The mains
voltage has exceeded the upper
limit of the tolerance range (see
section "Technical data")
Remedy: Check the mains voltage
Cause: The earth current watchdog has
triggered the safety cut-out of
the power source.
Remedy: Switch off the power source,
wait for 10 seconds and then
switch it on again. If you have
tried this several times and the
error keeps recurring, contact
After-Sales Service.
Cause: Wire stick
Remedy: Correct wire short circuit
Cause: Ignition time-out function is act-
ive: no current started flowing
before the end of the time spe-
cified in the set-up menu. The
safety cut-out of the power
source has been triggered.
Remedy: Press the torch trigger
repeatedly; clean the workpiece
surface; if necessary, increase
the time until the safety cut-out
is triggered in the set-up menu:
level 2
Cause: Wire end - the wire-end check
option has detected that there is
no more welding wire available
Remedy: Insert new wirespool
186

Table of Contents

Other manuals for Fronius MagicWave 3000

Related product manuals