Mark WalkerSep 6, 2025
What happens when AC frequency is too high on Fronius Primo 3.0-1?
- KKevin SmithSep 6, 2025
If the AC frequency is too high, the Fronius Inverter will resume feeding energy into the grid.





What happens when AC frequency is too high on Fronius Primo 3.0-1?
If the AC frequency is too high, the Fronius Inverter will resume feeding energy into the grid.
What to do if error occurred during update process of Fronius Inverter?
If an error occurred during the update process of your Fronius Inverter, re-download the update file. If the status code is still displayed, notify a Fronius-trained service engineer.
What happens when AC voltage is too high on Fronius Inverter?
If the AC voltage is too high, the Fronius Inverter will resume feeding energy into the grid.
What happens when internal temperature is too high on Fronius Inverter?
When the internal temperature of your Fronius Inverter is too high, the inverter resumes with its start-up routine.
How to resolve functional incompatibility on Fronius Primo 3.0-1 Inverter?
To resolve functional incompatibility on your Fronius Inverter, update the inverter firmware. If the status code is still displayed, notify a Fronius-trained service engineer.
What to do if Fronius Primo 3.0-1 Inverter shows no communication with power stage set?
If your Fronius Inverter displays a status code indicating no communication with the power stage set continuously, notify a Fronius-trained service engineer.
How to fix invalid limit value settings on Fronius Primo 3.0-1 Inverter?
To address invalid limit value settings on your Fronius Inverter, update the inverter firmware. If the status code continues to appear, notify a Fronius-trained service engineer.
What causes LOW PV VOLTAGE on Fronius Primo 3.0-1?
The 'LOW PV VOLTAGE' status code on your Fronius Inverter may appear due to the low level of insolation. If this status code occurs when there is sufficient insolation, contact your system engineer.
Why is my Fronius Inverter showing LOW PV OUTPUT?
A 'LOW PV OUTPUT' status code on your Fronius Inverter can be due to the low level of insolation. However, if this code appears when there is sufficient insolation, contact your system engineer.
What to do if Fronius Inverter shows Overcurrent (AC) error?
The fault should rectify automatically. However, if the Fronius Inverter continuously displays this status code, you should notify a Fronius trained service engineer.
| Purpose | Solar panel |
|---|---|
| Efficiency | 98 % |
| Output power | 3000 W |
| Input current | 12 A |
| Input voltage | 80 - 1000 V |
| Output voltage | - V |
| Input frequency | 50 - 60 Hz |
| Power supply type | Auto |
| Adjustable output voltage | - |
| International Protection (IP) code | IP65 |
| Product color | Black, Grey |
| Built-in display | Yes |
| Operating temperature (T-T) | -40 - 55 °C |
| Depth | 204 mm |
|---|---|
| Width | 431 mm |
| Height | 645 mm |
| Weight | 21500 g |
General operating instructions for the Fronius Primo inverter in English.
Essential safety rules and general precautions for inverter use.
Explanation of device concept, safety notices, and warning symbols.
Proper usage, warning labels on device, and specific notes for dummy devices.
Features and functions of the integrated WLAN system monitoring.
Identification of physical controls, status indicators, and function key operations.
Procedure for activating and deactivating the inverter's key lock feature.
Using USB for data logging, requirements, software updates, and safe removal.
Explains how status codes are displayed and interpreted, including class 1 and 3 codes.