472 Faulty fuse for solar module 
ground
1. Faulty fuse for solar module 
ground
1. Replace fuse
2. Incorrect setting in Basic 
Service menu
2. Set DC mode to "floating"
474 RCMU sensor fault 1. Rapidly changing insolation 
conditions
1. Automatic correction
2. Faulty sensor 2. Replace filter PC board
475 Insulation fault detected 1. Incorrect setting 1. Check ISO / GFDI setting
2. Grounding fault on PV gen-
erator
2. Check PV generator
3. Faulty power stage set 
measuring circuit
3. Replace DC PC board; re-
place AC PC board if neces-
sary
476 No internal power supply 1. Grid voltage too low 1. Check wiring
2. Grid test time too short 2. Power failure
3. Inadequate internal power 
supply
3. Replace AC PC board
4. Inadequate internal power 
supply
4. Replace filter PC board
480 Power stage set software 
and display software are in-
compatible
1. Old power stage set/display 
software
1. Software update
2. Old software 2. Reload setup
3. Incompatible hardware com-
bination
3. Check hardware compo-
nents
481 Recerbo has an old soft-
ware version
1. Old Recerbo software 1. Software update
2. Old software 2. Reload setup
3. Incompatible hardware com-
bination
3. Check hardware compo-
nents
482 Inverter switched off during 
start-up
1. Start-up process was unsuc-
cessful
1. Restart the inverter
483 Set DC2 fixed voltage is 
outside the permitted MPP 
range
1. Incorrectly set fixed voltage 1. Check the settings
484 - 485 Error during data transfer 1. Communication problem 
caused by temporary environ-
mental interference (grid, 
EMC, etc.)
1. Automatic correction
2. Check ribbon cable between 
filter PC board and power 
stage set
2. Replace ribbon cable
3. Faulty AC guard on filter PC 
board
3. Replace filter PC board
4. Faulty AC guard on power 
stage set
4. Replace AC PC board
Code Description Behaviour Remedy