997 Discrepancy between in-
verters
Discrepancy in the kWh value
between the inverters (depen-
dent on the settings in the Fro-
nius Solar.web)
Check settings in the system
management in Fronius So-
lar.web (actual Wpeak per in-
verter and threshold) and
inspect shadowing
998 Fronius Solar.net loop is
open 24h
Fronius Solar.net not closed
and the X-LED on the Datalog-
ger or Datamanager
1. Check Fronius Solar.net
loop
2. Check network cable
3. Check Fronius Com Card
999 No infeed for 24 h 1. No response from the invert-
er for 24 h -> message to Dat-
alogger or Datamanager
1. Check LED status of Data-
manager or Datalogger
2. No response from the Fro-
nius sensor card for 2 h ->
message to Datalogger or
Datamanager
2. Check archive values and
Fronius Solar.net loop
1000*–
1001*
Service messages Harmless if no errors have oc-
curred during grid power feed
operation; just give information
about the status of the internal
processor
1201*–
1210*
Service messages Harmless if no errors have oc-
curred during grid power feed
operation; just give information
about the status of the internal
processor
* ... Code only appears during event logging and in the error counter