Service, maintenance and disposal
General The cleaning device does not usually require maintenance. To ensure the cleaning
device remains operational over time, there are a number of care and mainten-
ance tasks that need to be carried out, however:
Before Every
Start-up
1
In general, you should visually inspect the cleaning device and ensure that
any damage is repaired immediately (before commissioning)
Weekly
1
Ensure that the cleaning blades can move easily
2
Ensure that the cleaning brushes are not worn
3
Empty the collecting container
Every 6 months
1
Open the device and check the pneumatic valves to ensure
-
No leaks
-
All screws are screwed tightly in place
-
All screw joints are fixed firmly in place on the pneumatic valves
Whenever Re-
quired
1
Open the device and
-
blast the inside of the device clean with dry and reduced compressed air
-
lightly oil the guides on the lifting device’s lifting cylinder
2
Change the cleaning blades—see description below
3
Change the cleaning brushes—see description below
4
Empty the collecting container
Changing the
Cleaning Blades
1
Set the “Calibrate cleaning head” input signal for one second
-
– this will move the cleaning head to the correct starting position
2
Deactivate the “Calibrate cleaning head” input signal
3
4
50