Proper use The solar inverter is intended exclusively to convert direct current from solar modules into
alternating current and to feed this into the public grid.
Utilisation not in accordance with the intended purpose comprises:
- utilisation for any other purpose or in any other manner
- making any modifications to the inverter that have not been expressly approved by
Fronius
- the installation of parts that are not distributed or expressly approved by Fronius.
Fronius shall not be liable for any damage resulting from such action.
No warranty claims will be entertained.
Proper use includes:
- carefully reading and obeying all the instructions and all the safety and danger notices
in the operating instructions
- performing all stipulated inspection and maintenance work
- installation as specified in the operating instructions
When designing the photovoltaic system, ensure that all of its components are operated
within their permitted operating ranges at all times.
Observe all the measures recommended by the solar module manufacturer to ensure the
lasting maintenance of the properties of the solar module.
Obey the regulations of the energy supply company regarding feeding energy into the grid.
Warning notices
on the device
There are warning notices and safety symbols on and in the inverter. These warning notic-
es and safety symbols must not be removed or painted over. They warn against operating
the device incorrectly, as this may result in serious injury and damage.
Safety symbols:
Risk of serious injury and damage due to incorrect operation
Do not use the functions described here until you have fully read and understood
the following documents:
- these operating instructions
- all the operating instructions for the system components of the photovoltaic
system, especially the safety rules
Fronius Symo
3.0-3-S / 3.7-3-S / 4.5-3-S
3.0-3-M / 3.7-3-M / 4.5-3-M
5.0-3-M / 6.0-3-M / 7.0-3-M
8.2-3-M
Fronius Symo
10.0-3-M / 12.5-3-M / 15.0-3-M
17.5-3-M / 20.0-3-M
Fronius Eco
25.0-3-S / 27.0-3-S
5
5
5
5
5

Table of Contents

Other manuals for Fronius Symo 8.2-3-M

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fronius Symo 8.2-3-M and is the answer not in the manual?

Fronius Symo 8.2-3-M Specifications

General IconGeneral
AC nominal output8.2 kW
Max. input voltage1000 V
MPPT voltage range200 - 800 V
Number of MPPT2
Protection classIP65
Frequency50 / 60 Hz
THD< 3%
Power factor (cos φac,r)0.85 - 1 ind./cap.
Efficiency98.1%
Operating Temperature Range-25°C to +60°C
Max. apparent AC power8200 VA
AC nominal voltage3 x 230 / 400 V