Fronius Datamanager 2.0
Controls, connec-
tions and dis-
plays on the
Fronius Dataman-
ager
No. Function
(1) IP switch
For switching the IP address:
Switch position A
Default IP address with opening of the WLAN access point
Fronius Datamanager 2.0 uses the set IP address 169.254.0.180 to establish a
direct connection to a PC via LAN.
Setting the IP switch to position A also opens an access point to enable a direct
WLAN connection to the Fronius Datamanager 2.0.
Access data for this access point:
Network name: FRONIUS_240.XXXXXX
Key: 12345678
Access to the Fronius Datamanager 2.0 is possible:
- Using the DNS name "http://datamanager"
- Using the IP address 169.254.0.180 for the LAN interface
- Using the IP address 192.168.250.181 for the WLAN access point
Switch position B
Assigned IP address
The Fronius Datamanager 2.0 uses an assigned IP address (factory setting dy-
namic (DHCP))
The IP address can be set on the Fronius Datamanager 2.0 website.
(5)
(1)
(6)(7)
(10) (8)(9)
(4)
(2)
(3)

Table of Contents

Other manuals for Fronius Symo 8.2-3-M

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fronius Symo 8.2-3-M and is the answer not in the manual?

Fronius Symo 8.2-3-M Specifications

General IconGeneral
AC nominal output8.2 kW
Max. input voltage1000 V
MPPT voltage range200 - 800 V
Number of MPPT2
Protection classIP65
Frequency50 / 60 Hz
THD< 3%
Power factor (cos φac,r)0.85 - 1 ind./cap.
Efficiency98.1%
Operating Temperature Range-25°C to +60°C
Max. apparent AC power8200 VA
AC nominal voltage3 x 230 / 400 V