Fitting the FPA15
board
(continued)
- Fasten the X3 cable (blue) (72) and
the by-pass capacitors (73) onto the
copper bracket (55), using the 5x12 -
TX20 screw (68)
- Tighten the 5x12 - TX20 screw (68)
with a torque of 2 Nm
- Plug the 10-pole Molex plug (41) onto
board LCA15
- Plug the 2-pole Molex plug (40) onto
board LCA15
- Arrange the ribbon cable (42) above
the cable harness, as shown in Fig.19
- Plug the ribbon cable (42) to board
FPA15 (5)
- Plug the “housing earth conductor”
(36) onto the housing box, in the
correct position
- Replace the housing box
- Screw the 5x25-TX20 screw (35) back
onto the rear of the housing
- Screw the 5x25-TX20 screw (34) back
onto the front of the housing
- Fit the carrying strap back on again
- Insert the board insulator (37)
- Insert the housing stiffening element
(21)