EFd | 81, EFd | 83
Cause: Fault in the wire feed system (overcurrent in wire-feed unit drive)
Remedy: Arrange the hosepack in as straight a line as possible; check that there are
no kinks or dirt in the inner liner; check the contact pressure on the 4 roller
drive
Cause: Wire-feed unit motor is sticking or defective
Remedy: Check the wire-feed unit motor or contact After-Sales Service
to0 | xxx
Note: xxx stands for a temperature value
Cause: Overtemperature in the primary circuit of the power source
Remedy: Allow power source to cool down, check air filter and clean if necessary,
check that fan is on
to1 | xxx
Note: xxx stands for a temperature value
Cause: Overtemperature on the booster located in the power source
Remedy: Allow power source to cool down, check air filter and clean if necessary,
check that fan is on
to2 | xxx
Note: xxx stands for a temperature value
Cause: Overtemperature in the secondary circuit of the power source
Remedy: Allow power source to cool down, check that fan is on
to3 | xxx
Remark: xxx stands for a temperature value
Cause: Overtemperature in the wire-feed unit motor
Remedy: Allow wire-feed unit to cool down
to4 | xxx
Remark: xxx stands for a temperature value
Cause: Overtemperature in welding torch
Remedy: Allow welding torch to cool down
to5 | xxx
Note: xxx stands for a temperature value
Cause: Overtemperature in cooling unit
Remedy: Allow cooling unit to cool down, check that fan is on
to6 | xxx
Note: xxx stands for a temperature value
Cause: Overtemperature at the transformer of the power source
Remedy: Allow power source to cool down, check air filter and clean if necessary,
check that fan is on