EasyManua.ls Logo

Fronius TransSteel 2500c - Tst 2700 C MV

Fronius TransSteel 2500c
120 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
111
EN
TSt 2700c MV
Mains voltage (U
1
) 3 x 200 V 230 V
Max. effective primary current (I
1eff
) 13.3 A 11.6 A
Max. primary current (I
1max
) 25.7 A 22.41A
Mains fuse protection (slow-blow) 25 A
Mains voltage (U
1
) 3 x 380 V 400 V 460 V
Max. effective primary current (I
1eff
) 7 A 6.6 A 5.8 A
Max. primary current (I
1max
) 13.1 A 12.5 A 10.8 A
Mains fuse protection (slow-blow) 15 A
Apparent power at 400 V AC 8,66 kVA
Mains voltage (U
1
) 1 x 230 V 240 V 240 V 240 V
Max. effective primary current (I
1eff
) 16.0 A 15.0 A 18.1 A 18.1 A
Max. primary current (I
1max
) 22.3 A 23.9 A 24.9 A 28.1 A
Mains fuse protection (slow-blow) 16 A 15 A 20 A 30 A
Apparent power 5.13 kVA 5.74 kVA 5.98 kVA 6.74 kVA
Mains voltage tolerance -10 / +15 %
Mains frequency 50 / 60 Hz
Max. permitted mains impedance Z
max
on PCC
1)
142 mOhm
Welding current range (I
2
)
MIG / MAG 10 - 270 A
Rod electrode 10 - 270 A
Welding current range (I
2
) in single-phase operation
MIG / MAG 10 - 220 A
Rod electrode 10 -180 A
Welding current at 10 min / 40°C (104°F) 30% 60% 100%
U
1
= 200 - 230 V: 270 A 200 A 170 A
U
1
= 380 - 460 V: 270 A 200 A 170 A
Welding current in sin-
gle-phase operation at
10 min / 40°C (104°F) 15%
2)
100%
U
1
= 230 V: Fuse 16 A 180 A 145 A
Welding current in sin-
gle-phase operation at
10 min / 40°C (104°F) 8%
2)
100%
U
1
= 240 V: Fuse 15 A 180 A 145 A
Welding current in sin-
gle-phase operation at
10 min / 40°C (104°F) 11%
2)
100%
U
1
= 240 V: Fuse 20 A 200 A 160 A
Welding current in sin-
gle-phase operation at
10 min / 40°C (104°F) 40%
2)
100%
U
1
= 240 V: Fuse 30 A 220 A 160 A
Output voltage range according to standard characteristic (U
2
)
MIG / MAG 14.5 - 34.3 V
Rod electrode 20.4 - 34.3 V

Table of Contents