83
EN
Setting range: OFF, 5 - 100 (OFF, 0.2 - 3.94)
Factory setting: OFF
SPt Spot time - spot / stitch welding time
Unit: s
Setting range: OFF, 0.1 - 5
Factory setting: OFF
SPb Spot break - stitch pause time
Unit: s
Setting range: OFF, 0.1 - 10 (in 0.1 s increments)
Factory setting: OFF
FAC Factory - reset power source to factory settings
Press and hold down one of the "Parameter selection" buttons for 2 s to restore the
factory settings
- when "PrG" appears on the digital display, the power source has been reset
IMPORTANT! When the power source is reset, all personal settings in the Setup
menu are lost.
Operating points that were saved using the "Save" buttons are retained when the
power source is reset. The functions in the second level of the Setup menu (2nd)
are also not deleted. Exception: Ignition time-out function parameter (ito).
2nd Second level of the Setup menu (see "Setup menu - level 2")
NOTE! The "Ignition time-out" function (ito) is a safety function. The length of
wire that is fed before the safety cut-out trips may differ from the preset wire
length, particularly when the wire is being fed at high speeds.