SPt Spot time - spot / stitch welding time
Unit: s
Setting range: OFF, 0.1 - 5
Factory setting: OFF
SPb Spot break - stitch pause time
Unit: s
Setting range: OFF, 0.1 - 10 (in 0.1 s increments)
Factory setting: OFF
FAC Factory - reset power source to factory settings
Press and hold down one of the "Parameter selection" buttons for 2 s to restore the
factory settings
- when "PrG" appears on the digital display, the power source has been reset.
IMPORTANT! When the power source is reset, all personal settings in the Setup
menu are lost.
When the power source is reset, operating points that were saved using the "Save"
buttons are not deleted, but are retained in the memory. The functions in the sec-
ond level of the Setup menu (2nd) are also not deleted. Exception: Ignition time-
out function parameter (ito).
2nd Second level of the Setup menu (see "Setup menu - level 2")
NOTE! The "Ignition time-out" function (ito) is a safety function. The length of
wire that is fed before the safety cut-out trips may differ from the preset wire
length, particularly when the wire is being fed at fast wire feed speeds.
The "Ignition time-out" function (ito) is explained in the "Special functions and
options" section.