Factory setting: 2T (2-step)
FAC Reset power source to factory settings
Press and hold one of the "Parameter selection" buttons for two seconds to
restore the factory settings
- when "PrG" appears on the digital display, the power source has been reset
IMPORTANT! If the power source is reset, all the personal settings in the Setup
menu are lost.
Operating points stored using save buttons remain stored when the power
source is reset. The functions in the second level of the setup menu (2nd) are
also not deleted. Exception: Ignition time-out function parameter (ito).
2nd Second level of the Setup menu (see "Setup Menu 2nd Level")
Setup parameters
for MMA welding
IMPORTANT! When resetting the power source using the Factory FAC setup parameter,
the hot current time (Hti) and HotStart current (HCU) setup parameters are also reset.
HCU HotStart current
Unit: %
Setting range: 100 - 200
Factory setting: 150
Hti Hot current time
Unit: s
Setting range: 0 - 2.0
Factory setting: 0.5
ASt Anti-stick
Unit: -
Setting range: On, OFF
Factory setting: OFF
FAC Reset power source to factory settings
Press and hold one of the "Parameter selection" buttons for two seconds to
restore the factory settings - when "PrG" appears on the digital display, the power
source has been reset.
IMPORTANT! If the power source is reset, all the personal settings are lost.
Operating points stored using save buttons are not deleted when the power
source is reset - they remain stored. The functions in the second level of the
setup menu (2nd) are also not deleted. Exception: Ignition time-out function para-
meter (ito).
2nd Second level of the Setup menu (see "Setup Menu 2nd Level")
Parameters for
TIG welding
F-P Pulse frequency
Unit: Hertz
Setting range: OFF; 1 - 990
(up to 10 Hz: in 0.1 Hz increments)
(up to 100 Hz: in 1 Hz increments)
(over 100 Hz: in 10 Hz increments)
105
EN-US

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fronius TransSteel 3000c Pulse and is the answer not in the manual?

Fronius TransSteel 3000c Pulse Specifications

General IconGeneral
BrandFronius
ModelTransSteel 3000c Pulse
CategoryWelding System
LanguageEnglish

Related product manuals