ESr | 20
The cooling unit used is not compatible with the power source
Connect compatible cooling unit
Cause:
Remedy:
ELn | 8
The connected wirefeeder is not supported
Connect supported wirefeeder
Cause:
Remedy:
ELn | 12
Different control panels for selecting materials are in the system
Connect similar control panels to select materials
Cause:
Remedy:
ELn | 13
Impermissible change of welding process during welding
During welding do not make any impermissible change to the welding pro-
cess, reset error message by pressing any button
Cause:
Remedy:
ELn | 14
More than one robot interface is connected
Only one robot interface may be connected, check the system configuration
Cause:
Remedy:
ELn | 15
More than one remote control is connected
Only one remote control may be connected, check the system configuration
Cause:
Remedy:
Err | IP
The power source control has detected a primary overvoltage
Check the grid voltage.
If the service code persists, switch off the power source, wait for 10 seconds
and then switch the power source on again.
If the error still persists, contact the After-Sales Service team
Cause:
Remedy:
Err | PE
The earth current watchdog has triggered the safety cut-out of the power
source.
Switch off the power source
Place the power source on an insulating surface
Connect the grounding cable to a section of the workpiece that is closer to
the arc
Wait for 10 seconds and then switch the power source on again
If you have tried this several times and the error keeps recurring, contact
the After-Sales Service team
Cause:
Remedy:
PHA | SE1
The power source is being used in single-phase mode
-
Cause:
Remedy:
PHA | SE3
The power source is being used in three-phase mode
-
Cause:
Remedy:
Err | 51
Mains undervoltage: the grid voltage has fallen below the tolerance range
Check the grid voltage. If the service code persists, contact the After-Sales
Service team
Cause:
Remedy:
118

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fronius TransSteel 3000c Pulse and is the answer not in the manual?

Fronius TransSteel 3000c Pulse Specifications

General IconGeneral
BrandFronius
ModelTransSteel 3000c Pulse
CategoryWelding System
LanguageEnglish

Related product manuals