Err | 52
Mains overvoltage: the grid voltage has risen above the tolerance range
Check the grid voltage. If the service code persists, contact the After-Sales
Service team
Cause:
Remedy:
EFd 5
Incorrect wirefeeder connected
Connect correct wirefeeder
Cause:
Remedy:
EFd 8
Wirefeeder overtemperature
Allow wirefeeder to cool down
Cause:
Remedy:
EFd | 81, EFd | 83
Fault in the wirefeed system (overcurrent in wirefeeder drive)
Arrange the hosepack in as straight a line as possible; check that there are
no kinks or dirt in the inner liner; check the contact pressure on the 4 roller
drive
Wirefeeder motor is sticking or faulty
Check the wirefeeder motor or contact the After-Sales Service team
Cause:
Remedy:
Cause:
Remedy:
to0 | xxx
Note: xxx stands for a temperature value
Overtemperature in the primary circuit of the power source
Allow power source to cool down, check air filter and clean if necessary,
check that fan is on
Cause:
Remedy:
to1 | xxx
Note: xxx stands for a temperature value
Overtemperature on the booster located in the power source
Allow power source to cool down, check air filter and clean if necessary,
check that fan is on
Cause:
Remedy:
to2 | xxx
Note: xxx stands for a temperature value
Overtemperature in the secondary circuit of the power source
Allow power source to cool down, check that fan is on
Cause:
Remedy:
to3 | xxx
Note: xxx stands for a temperature value
Overtemperature in wirefeeder motor
Allow wirefeeder to cool down
Cause:
Remedy:
to4 | xxx
Note: xxx stands for a temperature value
Overtemperature in welding torch
Allow welding torch to cool down
Cause:
Remedy:
119