EasyManua.ls Logo

Fronius TransSteel 3000c Pulse - Page 120

Fronius TransSteel 3000c Pulse
140 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
to5 | xxx
Note: xxx stands for a temperature value
Overtemperature in cooling unit
Allow cooling unit to cool down, check that fan is on
Cause:
Remedy:
to6 | xxx
Note: xxx stands for a temperature value
Overtemperature on the power source transformer
Allow power source to cool down, check air filter and clean if necessary,
check that fan is on
Cause:
Remedy:
to7 | xxx
Note: xxx stands for a temperature value
Overtemperature in the power source
Allow power source to cool down, check air filter and clean if necessary,
check that fan is on
Cause:
Remedy:
tu0 | xxx
Note: xxx stands for a temperature value
Undertemperature in the power source primary circuit
Place power source in a heated room and allow it to warm up
Cause:
Remedy:
tu1 | xxx
Note: xxx stands for a temperature value
Undertemperature on the booster located in the power source
Place power source in a heated room and allow it to warm up
Cause:
Remedy:
tu2 | xxx
Note: xxx stands for a temperature value
Undertemperature in the power source secondary circuit
Place power source in a heated room and allow it to warm up
Cause:
Remedy:
tu3 | xxx
Note: xxx stands for a temperature value
Undertemperature in the wirefeeder motor
Place wirefeeder in a heated room and allow to warm up
Cause:
Remedy:
tu4 | xxx
Note: xxx stands for a temperature value
Undertemperature in the welding torch
Place welding torch in a heated room and allow to warm up
Cause:
Remedy:
tu5 | xxx
Note: xxx stands for a temperature value
Undertemperature in the cooling unit
Place cooling unit in a heated room and allow to warm up
Cause:
Remedy: