tu6 | xxx
Note: xxx stands for a temperature value
Undertemperature on the power source transformer
Place power source in a heated room and allow it to warm up
Cause:
Remedy:
tu7 | xxx
Note: xxx stands for a temperature value
Undertemperature in power source
Place power source in a heated room and allow it to warm up
Cause:
Remedy:
no | H2O
Coolant flow rate too low
Check coolant flow rate and cooling unit, including cooling circuit (for min-
imum coolant flow, see "Technical Data" chapter in the Operating Instruc-
tions for the device)
Cause:
Remedy:
hot | H2O
The coolant temperature is too high
Allow cooling unit and cooling circuit to cool down, until "hot | H2O" is no
longer displayed. Open the cooling unit and clean the cooler, check fan is
working properly.
Cause:
Remedy:
no | Prg
No preconfigured program has been selected
Select a configured program
Cause:
Remedy:
no | IGn
"Ignition time-out" function is active; current did not start flowing before the
length of wire specified in the Setup menu had been fed. The power source
safety cut-out has tripped
Shorten the wire stick-out; press the torch trigger again; clean the surface of
the workpiece; if necessary, set the "Ito" parameter in the Setup menu
Cause:
Remedy:
EPG | 17
The selected welding program is invalid
Select a valid welding program
Cause:
Remedy:
EPG | 29
The required wirefeeder is not available for the selected characteristic
Connect the correct wirefeeder, check the plug connections for the hosep-
ack
Cause:
Remedy:
EPG | 35
Measurement of the welding circuit resistance failed
Check grounding cable, current cable, or hosepack and replace if neces-
sary, re-measure the welding circuit resistance
Cause:
Remedy:
121