Displayed service
codes in connec-
tion with OPT
Easy Documenta-
tion
no | dAt
Welding is not possible
Date and time are not set on the power source
To reset the service code, press the arrow key;
Set date and time in the 2nd level of the service menu:
see page 97
Cause:
Remedy:
bAt | Lo
Welding is possible
The battery of OPT Easy Documentation is low
To reset the service code, press the arrow key;
Contact service (to change the battery)
Cause:
Remedy:
bAt | oFF
Welding is not possible
The battery of the OPT Easy Documentation is empty
To reset the service code, press the arrow key - the display shows no | dAt;
Contact service (to change the battery);
After changing the battery, the date and time in the are displayed in the 2nd
level of the service menu:
see page 97
Cause:
Remedy:
Err | doc
Welding is not possible
Error writing data;
Internal documentation error;
Communication error;
Turn power source off and on again
Cause:
Remedy:
Err | USb
Welding is not possible
Invalid file system on USB thumb drive;
General USB error
Unplug the USB thumb drive
Cause:
Remedy:
USB | full
Welding is not possible
The plugged in USB thumb drive is full
Unplug USB thumb drive, plug in new USB thumb drive
Cause:
Remedy:
122