Service, maintenance and disposal
General Under normal operating conditions, the welding system requires only a minimum of care
and maintenance. However, several points must be observed in order for the welding
system to remain operational for years to come.
Safety
WARNING!
An electric shock can be fatal.
Before opening the device
▶
Set power switch to - O - on the welding power supply
▶
Unplug the welding power supply from mains power
▶
Secure against anyone turning on power again
▶
Use a suitable measuring instrument to ensure that electrically charged components
(e.g., capacitors) are discharged
WARNING!
Work performed incorrectly can cause serious injury and damage.
▶
The following activities must only be carried out by trained and qualified personnel.
▶
Please note the information in the "Safety instructions" chapter!
At every start-up - Check mains plug and mains cable, as well as the welding torch, interconnecting
hosepack, and ground earth connection for damage
- Check if the all-round clearance of the device is 0.5 m (1 ft. 8 in.) so that cooling air
can circulate unimpeded
NOTE!
Air inlet and outlet openings must not be blocked or even partially covered.
Whenever
required
Remove the air filter on the rear of the housing from the side and clean it.
Every 2 Months
CAUTION!
Danger of damage to property.
▶
The air filter must only be fitted when dry.
▶
If required, clean air filter using dry compressed air or by washing it.
123
EN-US