101
EN
The special HF ignition indicator remains lit as long as a value has been specified
for the HF ignition parameter.
If the “HF ignition” set-up parameter is set to “OFF”, no high frequency ignition takes place
at the start of welding. In this case, welding starts with touchdown ignition.
rPI ignition
Reversed polarity ignition
Unit -
Setting range ON / OFF
Factory setting OFF
IMPORTANT! The rPI ignition function
- is only available on the MagicWave power source
- is not recommended for welding light-gauge sheets
L/R alignment
L (inductivity) - welding circuit inductivity (in microhenry)
R (resistance) - welding circuit resistance (in mOhm)
See the "L/R alignment" section for further details.
Ignition time-out
Time until safety cut-out is triggered after abortive ignition attempt
Unit s
Setting range 0,1 - 9,9
Factory setting 5
IMPORTANT! "Ignition Time-Out" is a safety function so it cannot be deactivated. A de-
scription of the ignition time out function may be found in the Chapter "TIG welding".
Arc break
Arc break watchdog
Time until safety cut-out following an arc break
Unit s
Setting range 0,1 - 9,9
Factory setting 2
IMPORTANT! The arc break watchdog is a safety function and cannot be deactivated. A
description of the arc break watchdog function may be found in the section "TIG welding".