EasyManua.ls Logo

Fronius TransTig 3000 Comfort - MMA Hotstart Function

Fronius TransTig 3000 Comfort
216 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
70
If necessary, additional welding parameters can be set in the set-up menu:
- Press the menu key
The relevant menu is displayed:
- Use the adjusting dial to select the desired set-up menu
- Open the selected set-up menu by pressing the adjusting dial
- Use the adjusting dial to select the welding parameter
- To change the welding parameter press the adjusting dial
- Change the welding parameter value using the adjusting dial
- Press the adjusting dial
- Exit the set-up menu
Start welding
Hotstart function To obtain optimum welding results, it will sometimes be necessary to adjust the hotstart
function.
Benefits
- Improved ignition, even when using electrodes with poor ignition properties
- Better fusion of the base material in the start-up phase, meaning fewer cold-shut de-
fects
- Largely prevents slag inclusions
For details on setting the available welding parameters, please refer to the "Rod elect. set-
up 2nd" section.
Example of hotstart function
Function:
during the specified hot-current time (Hti),
the welding current I
1
is increased to the
HotStart current HCU.
To activate the hotstart function, the Hot-
Start current HCU must be > 100.
NOTE! All welding parameter set values that have been set using the adjust-
ing dial remain stored until the next time they are changed. This applies even
if the power source is switched off and on again in the meantime.
5
6
I (A)
t (s)
0,5 1 1,5
Hti
I
1
HCU
100
150
Legend
Hti Hot-current time, 0-2 s, factory
setting: 0.5 s
HCU HotStart current, 0-200%,
factory setting 150%
I
1
Main current = set welding current

Table of Contents