(1).... Gas post-flow time at any given mo-
ment
(2).... Welding current at any given mo-
ment
G-H.... Post-flow lmax
G-L .... Post-flow lmin
Gas post-flow time as a function of the welding current
Gas qtity
Command value for protective gas shield flow (only with the "digital gas control" option)
Unit l/min cfh
Setting range OFF / 5.0 - max. OFF / 10.71 - max.
Factory setting 15 32.14
IMPORTANT! Please refer to "Digital Gas Control" operating instructions for more de-
tailed explanations of the "gas flow rate" welding parameter.
Gas correction
(only with the “Digital Gas Control“ option)
Unit -
Setting range AUT / 1.0 - 10.0
Factory setting AUT
IMPORTANT! Please refer to "Digital Gas Control" operating instructions for more de-
tailed explanations of the "gas correction" welding parameter.
Gas flushing
Purging of protective gas shield
Unit min
Setting range OFF / 0.1 - 10.0
Factory setting OFF
Purging of the protective gas shield begins as soon as "gas flushing" is allocated a value.
For safety reasons, purging of the shielding gas cannot be restarted until a new gas flush-
ing value is entered.
IMPORTANT! Purging of the protective gas shield is necessary if condensation forms
when the device is left unused in a cold environment for a prolonged period. Long hose-
packs are most affected.
I
min
I
max
I
t
G-H
G-L
(1)
(2)